Main Features
- Detonation & Deflagration Types.
- End - of - Line with “Weather Hood or Goose Neck.
- In - Line with Flanged or Screwed / Socket Weld ends.
- Different Types for every application.
- Fluidyne's precision-made crimped metal element.
- Plate stack type element.
- In - Line Threaded / B.W. / S. W
- MESG as per National Electric Code Hazardous Area Classification.
- Type Tested as Per API, ASME, CCOE, PESO Standards.
Design Codes for Fluidyne Flame Arrestors
- API 2000 & 2210
- EN- 12874 & EN 14491-2006 & EN-14494-2007
- ISO-16852
- IS- 11006& IS 2148
- IEC 60079
- ASME SEC VIII DIV I
Operation
Fluidyne API standard Flame Arrestors / Arresters are also known as Flame Traps. Fluidyne API standard Flame Arrestors are manufactured in various designs and applications like Detonation Flame Arrestors and Deflagration Flame Arrestors, In-Line and End-Of-Line Types. Flame Arrestors stop the propagation of a flame by absorbing and dissipating heat through the large surface area of the bank sheets. Ignited vapor attempting to pass through the arrestor is forced through small passages within the bank assembly. Heat is absorbed, lowering the temperature of the gas below its ignition point and quenching the flame. Flame Arresters are typically used in the chemical, petrochemical and pharmaceutical industries on applications such as storage tank facilities, flare stacks, incineration systems, storage tank roofs or digester convertor to prevent the propagation of confined and unconfined deflagrations. Detonation flame Arresters additionally stop the high pressures and velocities that can result in detonations. In case of ignition of vapors, they burn harmlessly at the flame arrestor, preventing ignition of vapors in the tank and subsequent explosion. Fluidyne Flame Arrestors, Detonation Flame Arrestors, Detonation Arrestors, Flame Detonation Arrestors are often used along with Breather valves. Kindly view our special section on ‘Breather Valves’.
Advantages of Fluidyne Flame Arrestors:
- They stop the spread or propagation of fire and flame.
- They control and prevent explosions in tanks and pipeline.
- They confine, enclose, control fire, flame and explosions.
- They protect valuable life, property and equipments.
Configuration
Fluidyne ‘Atmos’® Flame Arrestors are available for all common gas groupings to IEC or NEC codes, and supplied in range of sizes/materials/options; Net Free Area - three to four times inlet area, Bank Assembly - ostensible and removable. Special "off-set" housing design is not affected by condensate accumulation, even when installed in horizontal piping. The result is minimal pressure drop, increased flow capacity and heat dissipation. Ordering information given below.
Size: | Location: | Pressure Dop: | Materials: |
1" to 36" Refer graph for sizing. | Within 15' (4.6m) upstream of flame source. | Refer Graph, Should Not Exceed 1 PSI. | Low Copper Aluminum, Carbon Steel, SS 304/316 Stainless Steel. |
Codes: | Tests: | Element: | Installation: |
API, ASME, CCE, IS etc. | Type test, pressure drop test, flame propagation test, API 2000. | Plate stack or crimped metal | In-line, End-of-line, Inverted, Weather Hood etc. as per requirement. |
Our Other Products: Breather Valves, Emergency Vents, Gauge Hatch, Spark Arrestors.