All Fluidyne Breather Valves are available with flanged outlets or vented to atmosphere. Pressure/Vacuum Relief Valves are used mainly on bulk storage tanks, including fixed roof tanks with floating covers, to minimize evaporation loss. The Valves prevent the build-up of excessive pressure or vacuum which can unbalance the system or damage the storage vessel. Pressure and Vacuum protection are controlled with weight loaded pallets or springs loaded disc and the required Pressure/Vacuum settings are reached. Sometimes pressure settings require spring loaded disc and the vacuum settings use weight loaded pallet in one device. Fluidyne Breather Valves follow American Petroleum Institute Standard API 2000 or other applicable standard where tanks are generally large volume welded vessels that are built to API 650 standard. In order to accommodate large volumes at low set pressures, these Valves have ports that are larger in area than the inlet or nozzle connection. The low setting required generally require weight loaded disc or pallet and sometimes require spring loaded disc. Because of the above, a Breather Valve requires approximately 20% (minimum) to 100% over set pressure in order to reach full opening of the Valve.
DESIGN FEATURES :
Weight Loaded & Spring Loaded Types |
Pressure or Vacuum & Pressure cum Vacuum Types |
End - of - Line with “Weather Hood or In-Line Type. |
Breather Valve with Flame Arrestor Emergency Vents for Higher Flow |
Flanged or Screwed / Socket Weld ends |
Open to Atmosphere or Inlet –Outlet Types. |
Different Types for every application |
Type Tested as Per API, ASME, CCOE, PESO Standards |
DESIGN CODES
- API- 2000 & API 650
- API 520
- IS 10987
- EN-12874
- ASME SEC-VIII DIV I
Note: For Safety Fittings like Spark Arresters, Free Vents, Emergency-Conservation Vents, Dip Sticks Dip Rods Dip Gauges, Gauge Hatch, Vent Nuts/Caps, Syphon bush, Fill caps, Lightning Arresters, Tyrus Valve, and for more details on Safety Fittings please refer to our section or category section on 'Safety Fittings'.
Breather Valve Type: Standard (Model PV-100)
Fluidyne Standard Breather Valves (Model PV-100) are Dead Weight type having pressure and vacuum pallets. In case of over pressure, the pressure disc opens to release air or vapour to atmosphere and in case of over vacuum the vacuum disc open inward to admit air to neutralize the vacuum in tank.
Breather Valve Type: Spring & Dead Weight (Model PV-110)
Fluidyne Spring & Dead Weight (Model PV-110) are Dead Weight and Spring Type having pressure pallet and vacuum disc. In case of over pressure, the pressure palletalong with vacuum disc opens to release air or vapour to atmosphere and in case of vacuum the vacuum disc open inward into tank to admit air to neutralize the vacuum in tank. Here the Vacuum setting is adjustable.
Breather Valve Type: Tyrus (Model-120)
Fluidyne Spring & Dead Weight (Model PV-120) are Spring loaded type having pressure and vacuum discs. In case of over pressure, the pressure disc opens to release air or vapour to atmosphere and in case of over vacuum the vacuum disc open inward into tank to admit air to neutralize the vacuum. Here the Pressure and Vacuum settings are both adjustable.
Breather Valve Type: In-Line (Model-130)
Fluidyne Spring & Dead Weight (Model PV-130) are In-Line Weight and Spring loaded type having pressure and vacuum discs. In case of over pressure, the pressure disc along with vacuum disc opens to release air or vapour downstream and in case of vacuum the vacuum disc open inward into line to admit air or vapour downstream to neutralize the vacuum. Here the Vacuum setting is adjustable. Valve need to be installed vertically.
Pressure Relief Breather Valve Type: Dead Weight (Model P-100)
Fluidyne Standard Pressure Relief Breather Valve (Model P-100) is Dead Weight type having a pressure pallet. In case of over pressure, the pressure disc opens to release air or vapour to atmosphere. Here Pressure setting cannot be adjusted.
Pressure Relief Breather Valve Type: Spring Loaded (Model P-110)
Fluidyne Pressure Relief Breather Valve Spring Loaded Type (Model P-110) have spring loaded pressure pallet. In case of over pressure, the pressure disc opens to release air or vapour to atmosphere. Here Pressure setting can be adjusted.
Vacuum Relief Breather Valve Type: Standard (Model VB-100)
Fluidyne Standard Vacuum Relief Breather Valve Spring Loaded Type (Model VB-100) have spring loaded vacuum pallet. In case of over vacuum, the vacuum disc opens to allow airin to the tank. Here vacuum setting can be adjusted.
Vacuum Relief Breather Valve Type: In-Line (Model VB-110)
Fluidyne Vacuum Relief Breather Valve Spring Loaded In-Line Type (Model VB-110) have spring loaded vacuum disc. In case of over vacuum, the vacuum disc opens to allow air or vapour into the downstream. This valve can be also installed at end-of-line with end cap or weather hood as shown in the drawing. Here vacuum setting can be adjusted.
Vacuum Breaker Valve Type: Lever (Model VB-120)
Fluidyne Vacuum Relief In-Line Breather Valve Weight Loaded Lever Type (Model VB-120) have weight loaded lever operating the disc. In case of over vacuum, the vacuum disc opens to allow air gas or vapour into downstream side. Here vacuum setting can be adjusted by adjusting the weight position on lever. This valve can be installed both vertically or horizontally.
Vacuum Breaker Valve: Standard Dead Weight (Model VB-130)
Fluidyne Standard Vacuum Relief Breather Valve Dead Weight Type (Model VB-100) have weight loaded vacuum pallet. In case of over vacuum, the vacuum disc opens to allow air into the tank. Here vacuum setting cannot be adjusted.